On this page
Every DediJet server passes SMART and NVMe health checks during burn-in, before it joins the ready pool. Disks still wear out and occasionally fail, and they usually warn you first. Two tools read those warnings: smartctl (from smartmontools) for every disk type, and nvme-cli for NVMe drives.
Install the tools
On Ubuntu and Debian:
apt update
apt install -y smartmontools nvme-cliOn AlmaLinux and Rocky Linux:
dnf install -y smartmontools nvme-cliProxmox VE already includes smartmontools. List your disks with their serial numbers; ROTA = 1 means a spinning HDD:
lsblk -d -o NAME,MODEL,SERIAL,SIZE,ROTA,TRANRead SMART data on HDDs and SATA SSDs
smartctl -a /dev/sdaStart with the line SMART overall-health self-assessment test result. FAILED means the disk must be replaced. PASSED only means no attribute has crossed the vendor’s threshold yet, so read the attributes too, using the RAW_VALUE column:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 1874
194 Temperature_Celsius 0x0002 200 200 000 Old_age Always - 31
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0| Attribute | Meaning | Act when |
|---|---|---|
| 5 Reallocated_Sector_Ct | Bad sectors already replaced by spare ones | Non-zero and growing between checks |
| 197 Current_Pending_Sector | Unreadable sectors waiting to be remapped | Any non-zero value |
| 198 Offline_Uncorrectable | Sectors that failed during offline scans | Any non-zero value |
| 199 UDMA_CRC_Error_Count | Transfer errors between disk and controller, usually cabling or backplane | Increasing: open a ticket, the path is at fault rather than the media |
| 194 Temperature_Celsius | Current drive temperature | Above the maximum in the drive’s datasheet |
Attribute names and numbers vary by vendor, and SAS drives report Elements in grown defect list instead. For the full picture, including the drive’s own error log, use smartctl -x.
Read NVMe health
smartctl -a /dev/nvme0
nvme smart-log /dev/nvme0Both read the same health log. /dev/nvme0 is the controller; /dev/nvme0n1 is its namespace, the block device you partition.
Critical Warning: 0x00
Temperature: 38 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 1%
Data Units Written: 5,322,198 [2.72 TB]
Unsafe Shutdowns: 3
Media and Data Integrity Errors: 0
Error Information Log Entries: 0- Critical Warning must be
0x00. Any other value (spare below threshold, temperature, degraded reliability, read-only mode) needs attention now. - Available Spare is the reserve of replacement blocks. Once it drops below the threshold, the drive is near the end of its life.
- Percentage Used is the vendor’s estimate of rated endurance consumed. It can exceed 100% while the drive keeps working, but plan a replacement.
- Media and Data Integrity Errors should stay at 0. A growing count means the drive cannot reliably return your data.
- Error Information Log Entries often counts harmless events, such as unsupported commands sent by tools. It is not a failure signal on its own.
- Data Units Written counts units of 512,000 bytes; smartctl converts the total for you.
Run short and long self-tests
Self-tests run inside the drive’s firmware while the server keeps working. A short test usually takes two minutes or less; a long (extended) test reads the whole surface and can take many hours on large HDDs. smartctl prints the estimate when the test starts.
smartctl -t short /dev/sda
smartctl -t long /dev/sda
smartctl -l selftest /dev/sdaIn the log, Completed without error is what you want; Completed: read failure with an LBA number means the drive found unreadable sectors. For NVMe drives that support self-tests, use nvme-cli (code 1 = short, 2 = extended); an operation result of 0 in its log means success. smartctl can do the same from smartmontools 7.4 onwards.
nvme device-self-test /dev/nvme0 -s 1
nvme self-test-log /dev/nvme0Back up first. If a disk already shows pending sectors or media errors, copy your data off before you start a long test: a full surface read puts extra stress on a weak drive.
Schedule checks and email alerts with smartd
The smartd daemon checks every disk every 30 minutes and can start self-tests on a schedule. Edit /etc/smartd.conf (Debian, Ubuntu) or /etc/smartmontools/smartd.conf (AlmaLinux, Rocky Linux) and replace the existing DEVICESCAN line, because smartd ignores the lines that follow it:
DEVICESCAN -a -n standby,q -s (S/../.././02|L/../../6/03) -m you@example.com -M test-amonitors health status, attributes, error logs and self-test logs.-s (S/../.././02|L/../../6/03)starts a short test every day at 02:00 and a long test every Saturday at 03:00. On NVMe drives, scheduled self-tests need smartmontools 7.5 or later (check withsmartctl --version); older versions still monitor NVMe health.-msends alerts through themailcommand, so install a mail client and a transfer agent, for examplemailutilswith Postfix or msmtp.-M testsends one test email at startup. Remove it once the email has arrived.
Restart the daemon and check its log. On Ubuntu and Debian:
systemctl restart smartmontools
journalctl -u smartmontools -n 50On AlmaLinux and Rocky Linux, the service is named smartd: systemctl enable --now smartd, then journalctl -u smartd -n 50.
When to open a ticket
Replacing failed hardware is part of the service: under our SLA, a failed component is replaced within 4 hours of diagnosis, 24/7. Open a ticket when you see any of these:
- An overall assessment of
FAILED, or a failed self-test. - Reallocated sectors that keep growing, or any pending or offline-uncorrectable sectors.
- An NVMe critical warning other than
0x00, spare below threshold, or growing media errors. - A growing UDMA CRC error count.
- A disk that dropped out of your RAID array, or kernel messages such as
I/O erroror NVMe controller resets injournalctl -k.
Put everything in the first message to speed up the diagnosis:
- The server’s IP address and the disk you suspect, with its serial number from
smartctl -i. - The full output of
smartctl -xfor that disk, attached as a file. - With software RAID:
cat /proc/mdstatand the serial number of the disk that must stay in place. - Relevant kernel log lines with their timestamps, and whether your data is backed up.
With software RAID, follow Manage software RAID 1 with mdadm to prepare the array before the swap and rebuild it afterwards.
Next steps
- Measure performance with a repeatable method: Benchmark CPU, disks and network.
- Repair a system that no longer boots from rescue mode.